summaryrefslogtreecommitdiffstats
path: root/src/blueshift_drm.pyx
blob: f4bfc0673ef0a61976d39d5f437badfd2f940b9d (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
# -*- python -*-

# Copyright © 2014  Mattias Andrée (maandree@member.fsf.org)
# 
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
# 
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
# GNU General Public License for more details.
# 
# You should have received a copy of the GNU General Public License
# along with this program.  If not, see <http://www.gnu.org/licenses/>.

cimport cython
from libc.stdlib cimport malloc, free, realloc
from libc.stdint cimport *


cdef extern void blueshift_drm_close()
'''
Free all resources, but you need to close all connections first
'''

cdef extern int blueshift_drm_card_count()
'''
Get the number of cards present on the system

@return  The number of cards present on the system
'''

cdef extern int blueshift_drm_open_card(int card_index)
'''
Open connection to a graphics card

@param   card_index  The index of the graphics card
@return              -1 on failure, otherwise an identifier for the connection to the card
'''

cdef extern void blueshift_drm_update_card(int connection)
'''
Update the resource, required after `blueshift_drm_open_card`

@param  connection  The identifier for the connection to the card
'''

cdef extern void blueshift_drm_close_card(int connection)
'''
Close connection to the graphics card

@param  connection  The identifier for the connection to the card
'''

cdef extern int blueshift_drm_crtc_count(int connection)
'''
Return the number of CRTC:s on the opened card

@param   connection  The identifier for the connection to the card
@return              The number of CRTC:s on the opened card
'''

cdef extern int blueshift_drm_connector_count(int connection)
'''
Return the number of connectors on the opened card

@param   connection  The identifier for the connection to the card
@return              The number of connectors on the opened card
'''

cdef extern int blueshift_drm_gamma_size(int connection, int crtc_index)
'''
Return the size of the gamma ramps on a CRTC

@param   connection  The identifier for the connection to the card
@param   crtc_index  The index of the CRTC
@return              The size of the gamma ramps on a CRTC
'''

cdef extern int blueshift_drm_get_gamma_ramps(int connection, int crtc_index, int gamma_size,
                                              uint16_t* red, uint16_t* green, uint16_t* blue)
'''
Get the current gamma ramps of a monitor

@param   connection  The identifier for the connection to the card
@param   crtc_index  The index of the CRTC to read from
@param   gamma_size  The size a gamma ramp
@param   red         Storage location for the red gamma ramp
@param   green       Storage location for the green gamma ramp
@param   blue        Storage location for the blue gamma ramp
@return              Zero on success
'''

cdef extern int blueshift_drm_set_gamma_ramps(int connection, int crtc_index, int gamma_size,
                                              uint16_t* red, uint16_t* green, uint16_t* blue)
'''
Set the gamma ramps of the of a monitor

@param   connection  The identifier for the connection to the card
@param   crtc_index  The index of the CRTC to read from
@param   gamma_size  The size a gamma ramp
@param   red         The red gamma ramp
@param   green       The green gamma ramp
@param   blue        The blue gamma ramp
@return              Zero on success
'''

cdef extern void blueshift_drm_open_connector(int connection, int connector_index)
'''
Acquire information about a connector

@param  connection       The identifier for the connection to the card
@param  connector_index  The index of the connector
'''

cdef extern void blueshift_drm_close_connector(int connection, int connector_index)
'''
Release information about a connector

@param  connection       The identifier for the connection to the card
@param  connector_index  The index of the connector
'''

cdef extern int blueshift_drm_get_width(int connection, int connector_index)
'''
Get the physical width the monitor connected to a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   The physical width of the monitor in millimetres, 0 if unknown or not connected
'''

cdef extern int blueshift_drm_get_height(int connection, int connector_index)
'''
Get the physical height the monitor connected to a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   The physical height of the monitor in millimetres, 0 if unknown or not connected
'''

cdef extern int blueshift_drm_is_connected(int connection, int connector_index)
'''
Get whether a monitor is connected to a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   1 if there is a connection, 0 otherwise, -1 if unknown
'''

cdef extern int blueshift_drm_get_crtc(int connection, int connector_index)
'''
Get the index of the CRTC of the monitor connected to a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   The index of the CRTC
'''

cdef extern int blueshift_drm_get_connector_type_index(int connection, int connector_index)
'''
Get the index of the type of a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   The connector type by index, 0 for unknown
'''

cdef extern const char* blueshift_drm_get_connector_type_name(int connection, int connector_index)
'''
Get the name of the type of a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@return                   The connector type by name, "Unknown" if not identifiable,
                          "Unrecognised" if Blueshift does not recognise it.
'''

cdef extern long int blueshift_drm_get_edid(int connection, int connector_index, char* edid,
                                            long int size, int hexadecimal)
'''
Get the extended display identification data for the monitor connected to a connector

@param   connection       The identifier for the connection to the card
@param   connector_index  The index of the connector
@param   edid             Storage location for the EDID, it should be 128 bytes, 256 bytes + zero termination if hex
@param   size             The size allocated to `edid` excluding your zero termination
@param   hexadecimal      Whether to convert to hexadecimal representation, this is preferable
@return                   The length of the found value, 0 if none, as if hex is false
'''



cdef uint16_t* r_shared
'''
Non-threadsafe storage for the red colour curve to be used in native code
'''

cdef uint16_t* g_shared
'''
Non-threadsafe storage for the green colour curve to be used in native code
'''

cdef uint16_t* b_shared
'''
Non-threadsafe storage for the blue colour curve to be used in native code
'''

r_shared = NULL
g_shared = NULL
b_shared = NULL



def drm_close():
    '''
    Free all resources, but you need to close all connections first
    '''
    global r_shared, g_shared, b_shared
    # Deallocate colour curve storage
    if r_shared is not NULL:
        free(r_shared)
        r_shared = NULL
    if g_shared is not NULL:
        free(g_shared)
        g_shared = NULL
    if b_shared is not NULL:
        free(b_shared)
        b_shared = NULL
    # Close all native resources
    blueshift_drm_close()


def drm_card_count():
    '''
    Get the number of cards present on the system
    
    @return  :int  The number of cards present on the system
    '''
    return blueshift_drm_card_count()


def drm_open_card(int card_index):
    '''
    Open connection to a graphics card
    
    @param   card_index  The index of the graphics card
    @return  :int        -1 on failure, otherwise an identifier for the connection to the card
    '''
    return blueshift_drm_open_card(card_index)


def drm_update_card(int connection):
    '''
    Update the resource, required after `blueshift_drm_open_card`
    
    @param  connection  The identifier for the connection to the card
    '''
    blueshift_drm_update_card(connection)


def drm_close_card(int connection):
    '''
    Close connection to the graphics card
    
    @param  connection  The identifier for the connection to the card
    '''
    blueshift_drm_close_card(connection)


def drm_crtc_count(int connection):
    '''
    Return the number of CRTC:s on the opened card
    
    @param   connection  The identifier for the connection to the card
    @return  :int        The number of CRTC:s on the opened card
    '''
    return blueshift_drm_crtc_count(connection)


def drm_connector_count(int connection):
    '''
    Return the number of connectors on the opened card
    
    @param   connection  The identifier for the connection to the card
    @return  :int        The number of connectors on the opened card
    '''
    return blueshift_drm_connector_count(connection)


def drm_gamma_size(int connection, int crtc_index):
    '''
    Return the size of the gamma ramps on a CRTC
    
    @param   connection  The identifier for the connection to the card
    @param   crtc_index  The index of the CRTC
    @return  :int        The size of the gamma ramps on a CRTC
    '''
    return blueshift_drm_gamma_size(connection, crtc_index)


def drm_get_gamma_ramps(int connection, int crtc_index, int gamma_size, threadsafe = False):
    '''
    Get the gamma ramps of the of a monitor
    
    @param   connection                                 The identifier for the connection to the card
    @param   crtc_index                                 The index of the CRTC to read from
    @param   gamma_size                                 The size a gamma ramp
    @param   threadsafe:bool                            Whether to decrease memory efficiency and performace so
                                                        multiple threads can use DRM concurrently
    @return  :(r:list<int>, g:list<int>, b:list<int>)?  The current red, green and blue colour curves
    '''
    global r_shared, g_shared, b_shared
    cdef uint16_t* r
    cdef uint16_t* g
    cdef uint16_t* b
    # If not running in thread-safe mode,
    if not threadsafe:
        # allocate the shared storage space for colour curves
        # if not already allocated.
        if r_shared is NULL:
            r_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
        if g_shared is NULL:
            g_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
        if b_shared is NULL:
            b_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
    # If not thread-safe use those, otherwise allocate ad-hoc ones
    r = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else r_shared
    g = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else g_shared
    b = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else b_shared
    # Check for out-of-memory error, both for thread-safe and thread-unsafe
    if (r is NULL) or (g is NULL) or (b is NULL):
        raise MemoryError()
    # Get current curves
    rc = blueshift_drm_get_gamma_ramps(connection, crtc_index, gamma_size, r, g, b)
    if rc == 0:
        # If successful:
        # Move the C native colour curves to Python data structures
        rc_r, rc_g, rc_b = [], [], []
        for i in range(gamma_size):
            rc_r.append(r[i])
            rc_g.append(g[i])
            rc_b.append(b[i])
        # Then, if running in thread-safe mode,
        if threadsafe:
            # deallocate the ad-hoc curve storage.
            free(r)
            free(g)
            free(b)
        return (rc_r, rc_g, rc_b)
    else:
        # On failure,
        if threadsafe:
            # deallocate the ad-hoc curve storage
            # if running in thread-safe mode.
            free(r)
            free(g)
            free(b)
        return None


def drm_set_gamma_ramps(int connection, crtc_indices, int gamma_size, r_curve, g_curve, b_curve, threadsafe = False):
    '''
    Set the gamma ramps of the of a monitor
    
    @param   connection              The identifier for the connection to the card
    @param   crtc_indices:list<int>  The indices of the CRTC:s to control
    @param   gamma_size              The size a gamma ramp
    @param   r_curve:list<int>       The red gamma ramp
    @param   g_curve:list<int>       The green gamma ramp
    @param   b_curve:list<int>       The blue gamma ramp
    @param   threadsafe:bool         Whether to decrease memory efficiency and performace so
                                     multiple threads can use DRM concurrently
    @return  :int                    Zero on success
    '''
    global r_shared, g_shared, b_shared
    cdef uint16_t* r
    cdef uint16_t* g
    cdef uint16_t* b
    # If not running in thread-safe mode,
    if not threadsafe:
        # allocate the shared storage space for colour curves
        # if not already allocated.
        if r_shared is NULL:
            r_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
        if g_shared is NULL:
            g_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
        if b_shared is NULL:
            b_shared = <uint16_t*>malloc(gamma_size * sizeof(uint16_t))
    # If not thread-safe use those, otherwise allocate ad-hoc ones
    r = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else r_shared
    g = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else g_shared
    b = <uint16_t*>malloc(gamma_size * sizeof(uint16_t)) if threadsafe else b_shared
    # Check for out-of-memory error, both for thread-safe and thread-unsafe
    if (r is NULL) or (g is NULL) or (b is NULL):
        raise MemoryError()
    # Convert the Python colour curves to C native format
    for i in range(gamma_size):
        r[i] = r_curve[i] & 0xFFFF
        g[i] = g_curve[i] & 0xFFFF
        b[i] = b_curve[i] & 0xFFFF
    rc = 0
    # For each selected CRTC,
    for crtc_index in crtc_indices:
        # adjust the colour curves.
        rc |= blueshift_drm_set_gamma_ramps(connection, crtc_index, gamma_size, r, g, b)
    if threadsafe:
        # deallocate the ad-hoc curve storage
        # if running in thread-safe mode
        free(r)
        free(g)
        free(b)
    return rc


def drm_open_connector(int connection, int connector_index):
    '''
    Acquire information about a connector
    
    @param  connection       The identifier for the connection to the card
    @param  connector_index  The index of the connector
    '''
    blueshift_drm_open_connector(connection, connector_index)


def drm_close_connector(int connection, int connector_index):
    '''
    Release information about a connector
    
    @param  connection       The identifier for the connection to the card
    @param  connector_index  The index of the connector
    '''
    blueshift_drm_close_connector(connection, connector_index)


def drm_get_width(int connection, int connector_index):
    '''
    Get the physical width the monitor connected to a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :int             The physical width of the monitor in millimetres, 0 if unknown or not connected
    '''
    return blueshift_drm_get_width(connection, connector_index)


def drm_get_height(int connection, int connector_index):
    '''
    Get the physical height the monitor connected to a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :int             The physical height of the monitor in millimetres, 0 if unknown or not connected
    '''
    return blueshift_drm_get_height(connection, connector_index)


def drm_is_connected(int connection, int connector_index):
    '''
    Get whether a monitor is connected to a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :int             1 if there is a connection, 0 otherwise, -1 if unknown
    '''
    return blueshift_drm_is_connected(connection, connector_index)


def drm_get_crtc(int connection, int connector_index):
    '''
    Get the index of the CRTC of the monitor connected to a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :int             The index of the CRTC
    '''
    return blueshift_drm_get_crtc(connection, connector_index)


def drm_get_connector_type_index(int connection, int connector_index):
    '''
    Get the index of the type of a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :int             The connector type by index, 0 for unknown
    '''
    return blueshift_drm_get_connector_type_index(connection, connector_index)


def drm_get_connector_type_name(int connection, int connector_index):
    '''
    Get the name of the type of a connector
    
    @param   connection       The identifier for the connection to the card
    @param   connector_index  The index of the connector
    @return  :str             The connector type by name, "Unknown" if not identifiable,
                              "Unrecognised" if Blueshift does not recognise it.
    '''
    return (<bytes>blueshift_drm_get_connector_type_name(connection, connector_index)).decode('utf-8', 'replace')


def drm_get_edid(int connection, int connector_index):
    '''
    Get the extended display identification data for the monitor connected to a connector
    
    @param   connection        The identifier for the connection to the card
    @param   connector_index   The index of the connector
    @return  :str?             The extended display identification data for the monitor
    '''
    global edid_shared
    cdef long int size
    cdef long int got
    cdef char* edid
    cdef bytes rc
    
    # Prototype side of the hexadecimal representation
    # of the EDID, should be exact
    size = 256
    # Allocate storage space for the EDID, with one
    # extra character for NUL-termination
    edid = <char*>malloc((size + 1) * sizeof(char))
    # Check for out-of-memory error
    if edid is NULL:
        raise MemoryError()
    # Fill the storage space for the EDID, with the
    # EDID of the monitor connected to the selected
    # connector, in hexadecimal, representation.
    got = blueshift_drm_get_edid(connection, connector_index, edid, size, 1)
    
    # If the length of the EDID is zero,
    if got == 0:
        # the free the storage space,
        free(edid)
        # and return that it failed.
        return None
    
    # But if we got an non-zero length, it is of the
    # EDID's byte-length, not in hexadecimal representation
    # that is twice as long.
    if got * 2 > size:
        # In if that length is larger than we have anticipated,
        # update to new size (of the hexadecimal representation),
        size = got * 2
        # and reallocate the storage.
        edid = <char*>realloc(edid, (size + 1) * sizeof(char))
        # Check for out-of-memory error
        if edid is NULL:
            raise MemoryError()
        # Get the full EDID.
        got = blueshift_drm_get_edid(connection, connector_index, edid, size, 1)
        # Check that we got the EDID. There is an unlikely
        # race condition where the user can have unplugged
        # the monitor.
        if got == 0:
            # If we did not get an EDID,
            # free the storage for it,
            free(edid)
            # and return that it failed.
            return None
        # If we got a large EDID yet,
        if got * 2 > size:
            # ignore it because it should happen,
            # EDID:s are 128 bytes long and the risk that
            # the use plugged in new monitor that did not
            # have the same EDID format, is super unlikely.
            # She would have to pause the program or used
            # a KVM switch between the two readings.
            # Instead just truncate the EDID to the size
            # that we expected; it is not fatal.
            got = size // 2
    
    # NUL-terminate the EDID,
    edid[got * 2] = 0
    # and convert it to bytes so that we can
    # later convert it to a Python string,
    rc = edid
    # and deallocate the C string.
    free(edid)
    # Convert the EDID to a Sython string
    return rc.decode('utf-8', 'replace')