summaryrefslogtreecommitdiffstats
path: root/src
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--src/blueshift_drm.pyx53
1 files changed, 50 insertions, 3 deletions
diff --git a/src/blueshift_drm.pyx b/src/blueshift_drm.pyx
index 7de8c70..16ad4a5 100644
--- a/src/blueshift_drm.pyx
+++ b/src/blueshift_drm.pyx
@@ -16,7 +16,7 @@
# along with this program. If not, see <http://www.gnu.org/licenses/>.
cimport cython
-from libc.stdlib cimport malloc, free
+from libc.stdlib cimport malloc, free, realloc
from libc.stdint cimport *
@@ -516,22 +516,69 @@ def drm_get_edid(int connection, int connector_index):
cdef char* edid
cdef bytes rc
+ # Prototype side of the hexadecimal representation
+ # of the EDID, should be exact
size = 256
+ # Allocate storage space for the EDID, with one
+ # extra character for NUL-termination
edid = <char*>malloc((size + 1) * sizeof(char))
+ # Check for out-of-memory error
if edid is NULL:
raise MemoryError()
+ # Fill the storage space for the EDID, with the
+ # EDID of the monitor connected to the selected
+ # connector, in hexadecimal, representation.
got = blueshift_drm_get_edid(connection, connector_index, edid, size, 1)
+ # If the length of the EDID is zero,
if got == 0:
+ # the free the storage space,
free(edid)
+ # and return that it failed.
return None
+ # But if we got an non-zero length, it is of the
+ # EDID's byte-length, not in hexadecimal representation
+ # that is twice as long.
if got * 2 > size:
- size = got
- blueshift_drm_get_edid(connection, connector_index, edid, size, 1)
+ # In if that length is larger than we have anticipated,
+ # update to new size (of the hexadecimal representation),
+ size = got * 2
+ # and reallocate the storage.
+ edid = <char*>realloc(edid, (size + 1) * sizeof(char))
+ # Check for out-of-memory error
+ if edid is NULL:
+ raise MemoryError()
+ # Get the full EDID.
+ got = blueshift_drm_get_edid(connection, connector_index, edid, size, 1)
+ # Check that we got the EDID. There is an unlikely
+ # race condition where the user can have unplugged
+ # the monitor.
+ if got == 0:
+ # If we did not get an EDID,
+ # free the storage for it,
+ free(edid)
+ # and return that it failed.
+ return None
+ # If we got a large EDID yet,
+ if got * 2 > size:
+ # ignore it because it should happen,
+ # EDID:s are 128 bytes long and the risk that
+ # the use plugged in new monitor that did not
+ # have the same EDID format, is super unlikely.
+ # She would have to pause the program or used
+ # a KVM switch between the two readings.
+ # Instead just truncate the EDID to the size
+ # that we expected; it is not fatal.
+ got = size // 2
+ # NUL-terminate the EDID,
edid[got * 2] = 0
+ # and convert it to bytes so that we can
+ # later convert it to a Python string,
rc = edid
+ # and deallocate the C string.
free(edid)
+ # Convert the EDID to a Sython string
return rc.decode('utf-8', 'replace')